Operating mode
Charging on the power that would otherwise be exported
The whole point of surplus charging sits in the gap between what an imported kilowatt-hour costs and what an exported one earns. Making it work means knowing second by second how much is spare, and tracking charging power to exactly that.
The floor nobody mentions
An electric car cannot be charged arbitrarily slowly. The standard's smallest step is about 6 amperes — roughly 1.4 kW on one phase, 4.2 kW on three. With 800 watts spare on a March morning there is nothing to put into the car: below the step there is no “charge a little”, only on or off.
Everything else follows from that. Control worth having must not only track the surplus but be allowed to decide: wait until enough accumulates, top up a little from the grid, or drop to one phase to lower the floor.
- Smallest step
- ca. 6 A
- One phase from
- ca. 1,4 kW
- Three phases from
- ca. 4,2 kW
- Measuring point
- grid connection
- Inverter
- connected over Modbus TCP
- Control group
- charge points, heat pump, battery
Three charging priorities
Only sun, or full by morning?
Surplus charging is not a switch but a trade-off between price and deadline. With aCharge it is set per access medium — the person driving to a client tomorrow can hold a different priority than the one whose car stands until Monday, at the same wallbox.
Solar only
Charges only when there is enough surplus. No grid draw, no guarantee about the state of charge — the cheapest and the most patient setting.
Normal
Surplus first, grid when needed. The everyday setting: sun is used, but the car is not empty in the morning.
Maximum
As fast as the connection allows, regardless of the sun — for when a journey starts in two hours.
From the field
Where surplus charging fails
Four cases where everything is installed and grid power still ends up in the car.
The inverter is what gets measured
Then control sees generation instead of surplus and charges along whenever something else in the building draws. The measuring point belongs at the grid connection.
The house battery is quicker
Battery and wallbox reach for the surplus independently, the battery wins and the car gets nothing. Both belong in one control loop with a defined order.
Clouds switch charging on and off
Without hysteresis and a minimum run time the session starts and stops constantly — bad for the vehicle and for billing. Control has to be allowed to be sluggish.
The wallbox cannot switch phases
A device that only does three phases needs about 4.2 kW of surplus before anything happens at all — on a small array that means off for most of the year.